Caution:
For BI: p2649 = 1 signal, the following applies:
Motion starts without any explicit control signal.
Notice:
The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
Note:
This signal is only effective in the modes "traversing blocks" and "direct setpoint input/MDI".
When activating reject traversing tasks, then the axis brakes with the maximum deceleration (p2573).
p2642
CI: EPOS direct setpoint input/MDI position setpoint / MDI s_set
SERVO_S110-CAN
Can be changed: T
(EPOS),
Data type: Unsigned32 / Integer32
SERVO_S110-DP
P-Group: Basic positioner
(EPOS),
Not for motor type: -
SERVO_S110-PN
(EPOS)
Min
-
Description:
Sets the signal source for the position setpoint in the mode "direct setpoint input/MDI".
Dependency:
Refer to: p2648, p2649, p2650, p2690
Notice:
The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
Note:
Depending on p2649, the position setpoint is either transferred continuously or edge-triggered.
The position setpoint input is interpreted as length unit [LU].
p2643
CI: EPOS direct setpoint input/MDI velocity setpoint / MDI v_set
SERVO_S110-CAN
Can be changed: T
(EPOS),
Data type: Unsigned32 / Integer32
SERVO_S110-DP
P-Group: Basic positioner
(EPOS),
Not for motor type: -
SERVO_S110-PN
(EPOS)
Min
-
Description:
Sets the signal source for the velocity setpoint in the "direct setpoint input/MDI mode".
Dependency:
Refer to: p2649, p2650, p2691
Notice:
The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
Note:
Depending on p2649, the velocity setpoint is either transferred continuously or edge-triggered.
The velocity setpoint input is interpreted as [1000 LU/min].
p2644
CI: EPOS direct setpoint input/MDI acceleration override / MDI a_over
SERVO_S110-CAN
Can be changed: T
(EPOS),
Data type: Unsigned32 / FloatingPoint32
SERVO_S110-DP
P-Group: Basic positioner
(EPOS),
Not for motor type: -
SERVO_S110-PN
(EPOS)
Min
-
Description:
Sets the signal source for the acceleration override in the operating mode "direct setpoint input/MDI".
Dependency:
Refer to: p2649, p2650, p2692
Notice:
The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
Note:
Depending on p2649, the acceleration override is either transferred continuously or edge-triggered.
The signal value 4000 hex (16384 dec) corresponds to 100 %.
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
-
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
-
Calculated: -
Dynamic index: -
Units group: -
Scaling: PERCENT
Max
-
Parameter
List of parameters
Access level: 1
Func. diagram: 3618
Unit selection: -
Expert list: 1
Factory setting
2690[0]
Access level: 1
Func. diagram: 3618
Unit selection: -
Expert list: 1
Factory setting
2691[0]
Access level: 1
Func. diagram: 3618
Unit selection: -
Expert list: 1
Factory setting
2692[0]
1-399