Tekelec IP7 Secure Gateway Administration Manual page 636

Ip7 secure gateway
Table of Contents

Advertisement

Database Administration Manual - IP7 Secure
Gateway
CAPACITY (% FULL):
X-LIST ENTRIES ALLOCATED:
If the IPC being added to the database is not shown in the rtrv-dstn output, go to the "Adding
a Destination Point Code" procedure in the Database Administration Manual - SS7 and add the IPC
to the DPC table.
3. Add the remote application assignments using the ent-rmt-appl command.
For this example, enter these commands.
ent-rmt-appl:ipcn=p-16380:si=3:ssn=250
ent-rmt-appl:ipcn=p-16380:si=5
ent-rmt-appl:ipca=003-003-003:si=13
ent-rmt-appl:ipca=003-003-003:si=3:ssn=50:ssne=75
When each of these commands have successfully completed, the following message should appear.
rlghncxa03w 06-10-28 09:12:36 GMT EAGLE5 36.0.0
ENT-RMT-APPL:
4. Verify the changes using the rtrv-rmt-appl command.
This is an example of possible output:
rlghncxa03w 06-10-28 09:12:36 GMT EAGLE5 36.0.0
IPCA
003-003-003
IPCI
p-3-003-3
IPCN
p-16380
IPCN24
5. Back up the new changes, using the chg-db:action=backup:dest=fixed command.
These messages should appear; the active Maintenance and Administration Subsystem Processor
(MASP) appears first.
BACKUP (FIXED) : MASP A - Backup starts on active MASP.
BACKUP (FIXED) : MASP A - Backup on active MASP to fixed disk complete.
BACKUP (FIXED) : MASP A - Backup starts on standby MASP.
BACKUP (FIXED) : MASP A - Backup on standby MASP to fixed disk complete.
910-6278-001 Revision A, January 2012
MASP A - COMPLTD;
SI SSN
3 50-75, 100, 110-119, 200
5
13
SI SSN
3 5, 50-100, 250
5
SI SSN
3 250
5
SI SSN
1%
500
End Office Support