Gateway
0=Payload Protocol Indicator
1-31=Reserved
If the UA parameter set you wish to assign to the association does not contain the desired values,
perform
Changing a UA Parameter Set
CAUTION: Changing a UA parameter set may affect the performance of any
associations using the parameter set being changed.
Continue the procedure by performing one of these steps.
If the cwmin parameter value is not being changed, continue the procedure with
If the cwmin parameter value is being changed, continue the procedure with
9. To change the cwmin value, the new cwmin parameter value must be less than or equal to the
bufsize parameter value.
The cwmin parameter is the number if bytes specified for the association's congestion window.
The bufsize is the number of kilobytes specified for the size of the association's buffer. To
determine whether or not the cwmin value is less than or equal to the bufsize value, perform
one of these actions.
Multiply the bufsize value by 1024.
Divide the cwmin value by 1024.
Continue the procedure by performing one of these actions.
If the new cwmin value is less than or equal to the bufsize value, continue the procedure with
Step 10
.
If the new cwmin value is not less than or equal to the bufsize value, either choose another
value for the cwmin parameter that is less than or equal to the bufsize value, or
performChanging the Buffer Size of a M3UA or SUA Association
that the bufsize value is greater than or equal to the cwmin value. After the new cwmin value
has been chosen or the bufsize value has been changed, continue the procedure with
.
10. The remote hosts assigned to the association can be changed by specifying the rhost and
rhosttype parameters with the chg-assoc command.
If the primary and alternate remote hosts are not being changed in this procedure, or if only the
primary remote host is being changed, continue the procedure with
To change the alternate remote host value for the association, the association must have a primary
remote host assigned to it. If the association has a primary remote host, continue the procedure
with
Step
12. If the association does not have a primary remote host, continue the procedure with
Step
10.
11. Assign a primary remote host to the association by entering the chg-assoc command with the
name of the association and the primary remote host name.
For this example, enter this command.
chg-assoc:aname=assoc2:rhost= gw200.nc-tekelec.com
The rhosttype=primary parameter can be specified with the chg-assoc command, but is not
necessary.
910-6278-001 Revision A, January 2012
IETF M3UA and SUA Configuration Procedures
0=Big Endian , 1=Little Endian
to change the desired parameter set values.
Step 10
Step
9.
to change the bufsize value so
Step
12.
.
Step 10