Table 44: Valid Pvalue Parameter Values If Parm=3 - Tekelec IP7 Secure Gateway Administration Manual

Ip7 secure gateway
Table of Contents

Advertisement

Database Administration Manual - IP7 Secure
Gateway
Bits Enabled
Bit 2 - ASP AS State Query
Bit 0 - ASP Activate Notifications
Bit 2 - ASP AS State Query
Bit 1 - ASP Inactivate Notifications
Bit 2 - ASP AS State Query
Bit 0 - ASP Activate Notifications
Bit 1 - ASP Inactivate Notifications
Bit 2 - ASP AS State Query
* The system default value
If the parm value is 3, the bits used by the pvalue parameter are:
0 – UA Heartbeats – heartbeat messages are sent on connections from the Eagle 5 ISS to the
far-end node that are in the ASP-Down, ASP-Active, and ASP-Inactive states if the bit is enabled.
1 – UA Graceful Shutdown – enables the graceful shutdown of IPSG M3UA connections if the
bit is enabled.

Table 44: Valid PVALUE Parameter Values if PARM=3

parameter if the parm value is 3. The pvalue parameter value can be entered as a hexadecimal or
a decimal number.
Table 44: Valid PVALUE Parameter Values if PARM=3
Bits Enabled
None
Bit 0 - UA Heartbeats
Bit 1 - UA Graceful Shutdown
Bit 0 - UA Heartbeats
Bit 1 - UA Graceful Shutdown
910-6278-001 Revision A, January 2012
IETF M3UA and SUA Configuration Procedures
Bits Disabled
Bit 0 - ASP Activate Notifications
Bit 1 - ASP Inactivate Notifications
Bit 1 - ASP Inactivate Notifications
Bit 0 - ASP Activate Notifications
None
shows the values can be entered for the pvalue
Bits Disabled
Bit 0 - UA Heartbeats
Bit 1 - UA Graceful Shutdown
Bit 1 - UA Graceful Shutdown
Bit 0 - UA Heartbeats
None
Hexadecimal
Decimal
Value
Value
h'4
4
h'5
5
h'6
6
h'7
7
Hexadecimal
Decimal
Value
Value
h'0*
0*
h'1
1
h'2
2
h'3
3