Table 23: Ipgwx Signaling Link Parameter Combinations - Tekelec IP7 Secure Gateway Administration Manual

Ip7 secure gateway
Table of Contents

Advertisement

Database Administration Manual - IP7 Secure
Gateway
Link set table is ( 14 of 1024)
If the name of the linkset you wish to use is not shown in the MATELSN field of the rtrv-ls output,
repeat this step until all the IPGWx linksets have been displayed, or until a linkset has been found
that has the linkset you wish to use assigned as a mate. If the linkset you wish to use is not the
mate of another IPGWx linkset, continue the procedure with
If the name of the linkset you wish to use is shown in the MATELSN field of the rtrv-ls output,
perform the
Removing a Mate IPGWx Linkset from another IPGWx Linkset
linkset from the other linkset as a mate. Then continue the procedure with
If the desired linkset is the mate of another IPGWx linkset, and you do not wish to use this linkset,
perform the
Configuring an IPGWx Linkset
the procedure with
10. Add the signaling link to the database using the ent-slk command
Link Parameter Combinations
command.

Table 23: IPGWx Signaling Link Parameter Combinations

:loc = location of the IP card with one of these applications: SS7IPGW or IPGWI; and the DCM
card type. (See Note 6)
:link = A
:lsn = linkset name (See Notes 1, 2, 3, 4, and 5)
:slc = 0 - 15 (See Notes 4 and 5)
Notes:
1. If the multgc=yes parameter is assigned to the linkset, the card's application must be IPGWI.
2. The ipgwapc=yes parameter must be assigned to the linkset.
3. If the card's application is IPGWI, the linkset adjacent point code must be ITU. If the card's
application is SS7IPGW, the linkset adjacent point code must be ANSI. The domain of the linkset
adjacent point code must be SS7.
4. A linkset can contain only one signaling link assigned to the SS7IPGW or IPGWI applications
if the linkset contains a mate IPGWx linkset, or is the mate of an IPGWx linkset.
5. If the linkset does not have a mate IPGWx linkset assigned to it, or is not the mate of an IPGWx
linkset, the linkset can contain up to 8 signaling links assigned to the SS7IPGW or IPGWI
applications.
6. If the signaling link is being assigned to a single-slot EDCM, to maximize the performance of
the IPGWx cards assigned to the linkset, it is recommended that the all signaling links in the
linkset are assigned to single-slot EDCMs with part number 870-2372-xx.
For this example, enter these commands.
ent-slk:loc=2207:link=a:lsn=lsnlp3:slc=0
ent-slk:loc=2211:link=a:lsn=lsnlp4:slc=0
910-6278-001 Revision A, January 2012
1% full
procedure and add a new IPGWx linkset. Then continue
Step
10.
shows the parameters and values that can be specified with the ent-slk
IPGWx Signaling Link
IETF M3UA and SUA Configuration Procedures
Step
10.
Table 23: IPGWx Signaling
procedure to remove this
Step
10.
323

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the IP7 Secure Gateway and is the answer not in the manual?

Questions and answers

This manual is also suitable for:

Eagle

Table of Contents