Database Administration Manual - IP7 Secure
Gateway
CLLI
-----------
IPGWAPC MATELSN
yes
LOC
1107 A
Link set table is ( 14 of 1024)
4. To use the linkset shown in
linkset shown in
linkset shown in
If the linkset contains more than one signaling link, all but one of these signaling links must be
removed from the linkset. Perform the
these signaling links.
If you do not wish to change this linkset, or if the network type of the adjacent point codes of both
linksets are not the same, either choose another linkset from the rept-stat-iptps output in
1, and repeat
Step
and add a new linkset. Continue the procedure with
If the network types of the adjacent point codes of both linksets are the same, and the mate linkset
contains no more than one signaling link, do not perform the actions in this step. Continue the
procedure with
5. Display the status of the card containing the signaling link assigned to the linkset being changed
by entering the rept-stat-card command with the card location shown in the LOC field in the
rtrv-ls output in
Note: If the linkset that the mate linkset is being added to has no signaling links (see the rtrv-ls
Step
output in
rept-stat-card:loc=1103
This is an example of the possible output.
rlghncxa03w 08-04-27 17:00:36 GMT EAGLE5 38.0.0
CARD
VERSION
1103
114-000-000
ALARM STATUS
BPDCM GPL
IMT BUS A
IMT BUS B
SIGNALING LINK STATUS
SLK
PST
A
IS-NR
Command Completed.
6. Display the status of the signaling link assigned to the card shown in
rept-stat-slk command with the card location used in
this example, enter this command.
Note: If the status of the card shown in PST field in the rept-stat-card output in
OOS-MT-DSBLD, continue the procedure with
rept-stat-slk:loc=1103:link=a
910-6278-001 Revision A, January 2012
TFATCABMLQ MTPRSE ASL8
1
IPTPS LSUSEALM SLKUSEALM GTTMODE
---------- 10000 70
LINK SLC TYPE
0
SS7IPGW
Step 3
as a mate, the network type of the adjacent point code of the
Step 3
must be the same as the network type of the linkset shown in
Step 3
must not have more than one signaling link assigned to it.
3, and
Step 4
if necessary, or perform the
Step
5.
Step
2. For this example, enter this command.
2), continue the procedure with
TYPE
GPL
DCM
SS7IPGW
= No Alarms.
= 002-102-000
= Conn
= Conn
LS
lsgw1103
IETF M3UA and SUA Configuration Procedures
no
no
% 70
1% full
Removing an IPGWx Signaling Link
Configuring an IPGWx Linkset
Step
5.
Step
14.
PST
IS-NR
CLLI
-----------
Step 5
Step
14.
% CdPA
procedure to remove
SST
AST
Active
-----
Step 5
by entering the
and the link=a parameter. For
Step
2. The
Step
procedure
Step 5
is
307