Tekelec IP7 Secure Gateway Administration Manual page 1025

Ip7 secure gateway
Table of Contents

Advertisement

Database Administration Manual - IP7 Secure
Gateway
PARM
3: UA Serviceability Options.
PVALUE : Valid range = 32-bits
PARM
4: SCTP Payload Protocol Indicator byte order option. Bit indicates
PVALUE : Valid range = 32-bits
If
Step 2
was performed, for this example, enter this command.
rtrv-uaps:set=5
This is an example of possible output.
rlghncxa03w 10-07-28 09:12:36 GMT EAGLE5 42.0.0
SET
TIMER
5
5
5
5
5
5
5
5
5
5
TIMER 2: False IP Connection Congestion Timer, max time an
TVALUE : Valid range = 32-bits
TIMER 3: UA HeartBeat Period Timer T(beat), time (ms) between sending
TVALUE : Valid range = 32-bits
TIMER 4: UA HeartBeat Received Timer T(beat ack), timeout period for
TVALUE : Valid range = 32-bits
PARM
1: ASP SNM options.
PVALUE : Valid range = 32-bits
910-6278-001 Revision A, January 2012
enabled/disabled flag for a particular UA Serviceability
option. Supported on IPSG, SS7IPGW, and IPGWI applications.
UA Graceful Shutdown supported on IPSG for M3UA only.
BIT
0=UA Heartbeats
1=UA Graceful Shutdown
2-31=Reserved
PPI value is RCV/TX in Big Endian or Little Endian byte format.
Supported on IPSG-M2PA associations only.
BIT
0=Payload Protocol Indicator
1-31=Reserved
TVALUE
PARM
1
0
2
3000
3
10000
4
5000
5
0
6
0
7
0
8
0
9
0
10
0
10
association can be congested before failing due to false
congestion. SS7IPGW and IPGWI applications enforce
0-30000(ms). Not supported on IPSG application.
of BEAT msgs by NE. IPSG, SS7IPGW and IPGWI applications
enforce 100(ms)-60000(ms).
response BEAT ACK msgs by NE. IPSG, SS7IPGW and IPGWI
applications enforce 100(ms)-10000(ms).
flag for a particular ASP SNM option. Not supported on IPSG
application.
BIT
0=Broadcast
1=Response Method
2-5=Reserved
6=Broadcast Congestion Status Change 0=Disabled , 1=Enabled
7-31=Reserved
IPSG M2PA and M3UA Configuration Procedures
Each bit is used as an
BIT VALUE
0=Big Endian , 1=Little Endian
PVALUE
1
3
2
0
3
0
4
0
5
0
6
0
7
0
8
0
9
0
0
Each bit is used as an enabled/disabled
BIT VALUE
0=Disabled , 1=Enabled
0=Disabled , 1=Enabled
BIT VALUE
0=Disabled , 1=Enabled
0=Disabled , 1=Enabled
1025