Avaya S8700 Maintenance Manual page 1816

For multi-connect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

Maintenance-Object Repair Procedures
Table 8-449. Test #6 NPE Crosstalk Test — Continued
Error
Test
Code
Result
Description / Recommendation
1018
ABORT
Test disabled via administration. This only applies to analog stations. The
default for this field is y, so you may want to determine why it has been turned
off on this station.
1. To enable the test for the particular analog station being tested, enter the
2000
ABORT
Response to the test request was not received within the allowable time period.
1. Retry the command at 1-minute intervals up to 5 times.
2020
ABORT
The test did not run due to an already existing error on the specific port or a
more general circuit pack error.
1. Examine Error Log for existing errors against this port or the circuit pack
2100
ABORT
System resources required to run this test are not available. This could be due
to a failure to seize the port.
1. Retry the command at 1-minute intervals up to 5 times.
Any
FAIL
This test can fail due to on-board or off-board problems. Off-board problems of
concern include EXP-PN and EXP-INTF faults, TDM-BUS faults, and faults
associated with the tone detectors/tone generators. Clear every off-board
problem before replacing the board. Keep in mind that a TDM-BUS problem is
usually the result of a faulty board connected to the backplane or bent pins on
the backplane.
1. Resolve any EXP-PN and/or EXP-INTF errors.
2. Resolve any TDM-BUS errors.
3. Resolve any TONE-BD and/or TONE-PT errors.
4. Test the board when the faults from steps 1, 2, and 3 are cleared. Replace
8-1094
Issue 1 May 2002
change station extension command and change the
'Station' form from 'n' to 'y.'
and attempt to diagnose the already existing error.
the board only if the test fails.