JUNOSe 11.1.x Command Reference Guide A to M
load-interval
load-interval timeInterval
Syntax
no load-interval
Command introduced before JUNOSe Release 7.1.0.
Release Information
Sets the time interval at which the router calculates bit rates and packet rates for an
Description
interface. The no version restores the default value, 300 seconds. This command is
not available for the Ethernet interface on the SRP module.
Options
Interface Configuration
Mode
1230
load-interval
timeInterval Multiple of 30 seconds; in the range 30–300