JUNOSe 11.1.x Command Reference Guide A to M

mdl string

mdl string { eic eicValue | fic ficValue | lic licValue | unit unitValue | pfi pfiCode |
Syntax
port portValue | generator genValue }
no mdl string { eic | fic | lic | unit | pfi | port | generator }
Command introduced before JUNOSe Release 7.1.0.
Release Information
Allows you to specify an MDL message on a T3 interface as defined in the ANSI
Description
T1.107a-1990 specification. The no version restores the default value to the specified
MDL message or to all MDL messages.
Options
Controller Configuration
Mode
1304
mdl string
eicValue—Equipment identification code; 1–10 characters; default value is the
null value.
ficValue—Frame identification code; 1–10 characters; default value is the null
value.
licValue—Line identification code; 1–11 characters; default value is the null value.
unitValue—Unit identification code; 1–6 characters; default value is the null value.
pfiCode—Facility identification code to send in the MDL path message; 1–38
characters; default value is the null value.
portValue—Equipment port number to send in the MDL idle signal message;
1–38 characters; default value is the null value.
genValue Generator number to send in the MDL test signal message; 1–38
characters; default value is the null value.