mdt-data-holddown

mdt-data-holddown timeout
Syntax
no mdt-data-holddown
Command introduced in JUNOSe Release 8.2.0.
Release Information
Configures the time in seconds before switching back to the default MDT group from
Description
the data MDT group. The no version returns to the default.
Options
IP PIM Data MDT Configuration
Mode
timeout Time before switching back to the default MDT group, in the range
1–300 seconds; the default is 60