load-interval

load-interval seconds;
Syntax
Hierarchy Level
[edit interfaces dln unit logical-unit-number dialer-options],
[edit logical-systems logical-system-name interfaces dln unit logical-unit-number
Statement introduced before JUNOS Release 7.4.
Release Information
On J Series Services Routers with ISDN logical interfaces, specify the interval used
Description
to calculate the average load on the network. By default, the average interface load
is calculated every 60 seconds.
seconds
Options
interface—To view this statement in the configuration.
Required Privilege Level
interface-control—To add this statement to the configuration.
Related Topics
dialer-options]
—Number of seconds at which the average load calculation is triggered.
Range: 20 through 180, in 10-second intervals
Default: 60 seconds
Configuring ISDN Logical Interface Properties on page 875