Capture Max-Frame-Size; Capture Start - Avaya G450 Cli Reference Manual

Hide thumbs Also See for G450:
Table of Contents

Advertisement

CLI Commands

capture max-frame-size

Use the capture max-frame-size command to specify the maximum number of bytes
captured for each packet by the packet sniffer.
Syntax
capture max-frame-size max_frame_size
no capture max-frame-size
Parameters
Parameter
max_frame_size
User Level
read-write
Context
general
Example
To specify the maximum number of bytes captured for each packet by the packet sniffer as 68
bytes:
G450-001(super)# capture max-frame-size 68
Related Commands
capture
buffer-mode,
capture
start,
capture
capture,
show capture-buffer hex

capture start

Use the capture start command to start the packet sniffing service.
Note:
The capture start command resets the buffer before starting the sniffer.
Note:
640 Avaya G450 CLI Reference
Description
The maximum number of bytes captured
for each packet by the packet sniffer
capture
buffer-size,
capture
stop, capture-service,
filter-group,
capture
clear
capture-buffer,
ip
Packet sniffing
Possible
Default
Values
Value
14-4096
128
interface,
capture
ipsec,
capture-list, name,
show

Advertisement

Table of Contents
loading