Set Sync Switching - Avaya G450 Cli Reference Manual

Hide thumbs Also See for G450:
Table of Contents

Advertisement

Parameter
secondary
local
User Level
read-write
Context
general
Example
To set the primary clock as the clock source:
G450-001(super)# set sync source primary
If the secondary interface is not configured, the sync source set operation will fail:
G450-001(super)# set sync source secondary
Operation Failed
Cannot set the secondary clock source to be the active clock source
Related Commands
clear sync
interface,

set sync switching

Use the set sync switching command to toggle automatic failover and failback between
designated primary and secondary synchronization sources.
Syntax
set sync switching {enable | disable}
Description
Keyword specifying to set the secondary
clock source to be active, and the primary
clock source on standby
Keyword specifying to set the local clock to
be active
set sync
interface,
set sync
Possible
Values
switching,
show sync timing
Issue 1 January 2008
Synchronization
Default
Value
1123