Adc Start Of Conversion Trigx Input Select Register (Trigxsel); Adc Start Of Conversion Trigx Input Select Register (Trigxsel) Field Descriptions - Texas Instruments Concerto F28M36 Series Technical Reference Manual

Table of Contents

Advertisement

Analog-to-Digital Converter (ADC)

10.3.12.8 ADC Start of Conversion Trigx Input Select Register (TRIGxSEL)

Figure 10-48. ADC Start of Conversion Trigx Input Select Register (TRIGxSEL)
15
7
Reserved
R-0
LEGEND: R/W = Read/Write; R = Read only; -n = value after reset
Table 10-34. ADC Start of Conversion Trigx Input Select Register (TRIGxSEL) Field Descriptions
Bit
Field
15-5
Reserved
4-0
TRIGxSEL
934
Analog Subsystem
5
4
Value
Description
0
Reserved
Analog Trigger (TRIGx) MUX Input Select
00000
No selection (Disabled)
00001
TINT0 (CPU Timer 0)
00010
TINT1 (CPU Timer 1)
00011
TINT2 (CPU Timer 2)
00100
ADCEXTTRIG (C28 GPIO MUX)
00101
EPWM1SOCA (EPWM1)
00110
EPWM1SOCB (EPWM1)
00111
EPWM1SYNC (EPWM1)
01000
EPWM2SOCA (EPWM2)
01001
EPWM2SOCB (EPWM2)
01010
EPWM2SYNC (EPWM2)
01011
EPWM3SOCA (EPWM3)
01100
EPWM3SOCB (EPWM3)
01101
EPWM3SYNC (EPWM3)
01110
EPWM4SOCA (EPWM4)
01111
EPWM4SOCB (EPWM4)
10000
EPWM4SYNC (EPWM4)
10001
EPWM5SOCA (EPWM5)
10010
EPWM5SOCB (EPWM5)
10011
EPWM5SYNC (EPWM5)
10100
EPWM6SOCA (EPWM6)
10101
EPWM6SOCB (EPWM6)
10110
EPWM6SYNC (EPWM6)
10111
EPWM7SOCA (EPWM7)
11000
EPWM7SOCB (EPWM7)
11001
EPWM7SYNC (EPWM7)
11010
EPWM8SOCA (EPWM8)
11011
EPWM8SOCB (EPWM8)
11100
EPWM8SYNC (EPWM8)
11101
EPWM9SOCA (EPWM9)
11110
EPWM9SOCB (EPWM9)
11111
EPWM9SYNC (EPWM9)
Copyright © 2012–2019, Texas Instruments Incorporated
Reserved
R-0
TRIGxSEL
R/W-0
SPRUHE8E – October 2012 – Revised November 2019
www.ti.com
8
0
Submit Documentation Feedback

Advertisement

Table of Contents
loading