Control System: Acib Status Register (Ccibstatus); Control System: Acib Status Register (Ccibstatus) Field Descriptions - Texas Instruments Concerto F28M36 Series Technical Reference Manual

Table of Contents

Advertisement

Analog-to-Digital Converter (ADC)

10.3.12.4 Control System: ACIB Status Register (CCIBSTATUS)

Figure 10-44. Control System: ACIB Status Register (CCIBSTATUS)
15
7
LEGEND: R/W = Read/Write; R = Read only; -n = value after reset
Table 10-30. Control System: ACIB Status Register (CCIBSTATUS) Field Descriptions
Bit
Field
15-8
ASYSCLKCNT
7-3
Reserved
2
INT
1
READY
0
APGOODSTS
930
Analog Subsystem
Reserved
R-0
Value
Description
0-FFh
8-bit ACIB Bus Clock Counter
This is a free running counter clocked by the ACIB clock.
This counter indicates if the ACIB clock is present.
0
Reserved
INT signal state
Reads of this bit will give the current state of the INT signal.
READY signal state
Reads of this bit will give the current state of the READY signal.
Analog Subsystem Power Good Status
0
Power not present
1
Power present
Copyright © 2012–2019, Texas Instruments Incorporated
ASYSCLKCNT
R-0
3
SPRUHE8E – October 2012 – Revised November 2019
2
1
INT
READY
R-0
R-0
Submit Documentation Feedback
www.ti.com
8
0
Reserved
R-0

Advertisement

Table of Contents
loading

Table of Contents