Adc Start Of Conversion Trigger Overflow Detect Register (Trigovf); Adc Start Of Conversion Trigger Overflow Detect Register (Trigovf) Field Descriptions - Texas Instruments Concerto F28M36 Series Technical Reference Manual

Table of Contents

Advertisement

Analog-to-Digital Converter (ADC)

10.3.12.6 ADC Start of Conversion Trigger Overflow Detect Register (TRIGOVF)

Figure 10-46. ADC Start of Conversion Trigger Overflow Detect Register (TRIGOVF)
15
7
6
TRIG8
TRIG7
R-0
R-0
LEGEND: R/W = Read/Write; R = Read only; -n = value after reset
Table 10-32. ADC Start of Conversion Trigger Overflow Detect Register (TRIGOVF) Field
Bit
Field
15-8
Reserved
7
TRIG8
6
TRIG7
5
TRIG6
4
TRIG5
3
TRIG4
2
TRIG3
1
TRIG2
0
TRIG1
932
Analog Subsystem
5
4
TRIG6
TRIG5
R-0
R-0
Value
Description
0
Reserved
Indicates if overflow occurred on respective ADC trigger.
0
No overflow.
1
Overflow detected.
Indicates if overflow occurred on respective ADC trigger.
0
No overflow.
1
Overflow detected.
Indicates if overflow occurred on respective ADC trigger.
0
No overflow.
1
Overflow detected.
Indicates if overflow occurred on respective ADC trigger.
0
No overflow.
1
Overflow detected.
Indicates if overflow occurred on respective ADC trigger.
0
No overflow.
1
Overflow detected.
Indicates if overflow occurred on respective ADC trigger.
0
No overflow.
1
Overflow detected.
Indicates if overflow occurred on respective ADC trigger.
0
No overflow.
1
Overflow detected.
Indicates if overflow occurred on respective ADC trigger.
0
No overflow.
1
Overflow detected.
Copyright © 2012–2019, Texas Instruments Incorporated
Reserved
R-0
3
2
TRIG4
TRIG3
R-0
R-0
Descriptions
SPRUHE8E – October 2012 – Revised November 2019
www.ti.com
8
1
0
TRIG2
TRIG1
R-0
R-0
Submit Documentation Feedback

Advertisement

Table of Contents
loading

Table of Contents