3.7.7 Use cases of safety configurations

General
Configurations of lamp indicator and speed control are allowed to be modified in
RAPID programs, which are loaded to the system after the Collaborative Speed
Control add-in is installed.
Modifying lamp indicator colors
RGB of the LED lamp is controlled by values defined in RAPID instruction
SWIFTI_SetCustomizedLEDColor in routine SWIFTI_LedMain, which can affect
the color that the lamp shows. The routine exists in the system module SWIFTI_Main
of task T_SWIFTI_LED.
xx2200000434
The following table lists the logical value combinations and corresponding lamp
colors.
Color
White
Blue
Green
Red
Yellow
Cyan
Purple
Product manual - CRB 1300
3HAC083111-001 Revision: B
Note
Safety configurations can only be modified for robots running in RobotWare 7.6
and later versions.
Modified configuration must always be validated to verify that the desired safety
is achieved. If no validation is performed, or the validation is inadequate, the
configuration cannot be relied on for personal safety.
Parameter value 1
TRUE
FALSE
FALSE
TRUE
TRUE
FALSE
TRUE
© Copyright 2022-2023 ABB. All rights reserved.
3 Installation and commissioning
3.7.7 Use cases of safety configurations
Parameter value 2
Parameter value 3
TRUE
TRUE
FALSE
TRUE
TRUE
FALSE
FALSE
FALSE
TRUE
FALSE
TRUE
TRUE
FALSE
TRUE
Continues on next page