ABB CRB 1300 Product Manual page 457

Hide thumbs Also See for CRB 1300:
Table of Contents

Advertisement

Reconnecting the axis-4 motor connectors
1
2
3
4
Product manual - CRB 1300
3HAC083111-001 Revision: B
Action
Insert the male header of the motor connectors
to the connector plate.
Reconnect the connectors.
FB4
MP4
Tip
See the number markings on the connectors for
help to find the corresponding connector.
Route and secure the cabling with a cable strap.
Note
The motor cablings have another strap fixed. Pay
attention to the location where the new strap to
be fixed, see the figure as a guidance.
CAUTION
Correct cable routing is highly important.
If the cables are routed and secured incorrectly
the cables can be damaged.
Refit the connector plate.
© Copyright 2022-2023 ABB. All rights reserved.
5.5.3 Replacing the tubular and tilt unit
Note
xx2000001545
xx2000001544
xx2000001543
Screw: M4x8 12.9 Lafre
2C2B/FC6.9 (2 pcs)
Tightening torque: 2.6 Nm
xx2000001542
Continues on next page
5 Repair
Continued
457

Advertisement

Table of Contents
loading

Table of Contents