5 Repair
5.7.4 Replacing the axis-4 gearbox
Continued
6
7
Separating the housing
1
2
3
Continues on next page
642
Action
Carefully lift out the motor.
Remove the timing belt.
Action
DANGER
Make sure that all supplies for electrical power,
hydraulic pressure, and air pressure are turned
off.
Support the weight of the extender unit (only for
CRB 1300-7/1.4), tubular and tilt unit, and remove
the screws.
Valid for CRB 1300-11/0.9 and CRB 1300-10/1.15
Separate the tubular from the housing.
© Copyright 2022-2023 ABB. All rights reserved.
Note
xx2000001669
xx2000001670
Note
xx2000001671
xx2000001721
Product manual - CRB 1300