Disconnecting the axis-6 motor connectors
1
2
3
Disconnecting the axis-5 motor connectors
1
2
Product manual - CRB 1300
3HAC083111-001 Revision: B
Action
DANGER
Make sure that all supplies for electrical power,
hydraulic pressure, and air pressure are turned
off.
Disconnect the connectors.
MP6
FB6
Tip
Take photos of the connector and cable position
before disconnecting them, to have as a reference
when reconnecting.
Snap loose and remove the male head of the
connectors from the connector plate.
Action
DANGER
Make sure that all supplies for electrical power,
hydraulic pressure, and air pressure are turned
off.
Disconnect the connectors.
MP5
FB5
Tip
Take photos of the connector and cable position
before disconnecting them, to have as a reference
when reconnecting.
© Copyright 2022-2023 ABB. All rights reserved.
5 Repair
5.5.1 Replacing the lower arm
Continued
Note
xx2000001532
xx2000001533
Note
xx2000001534