Opening the connector interface plate
Notice that the procedure differs depending on if the connector interface is located
either at the rear or at the bottom of the base.
1
2
Disconnecting the earth cable
1
Product manual - CRB 1300
3HAC083111-001 Revision: B
Action
DANGER
Make sure that all supplies for electrical power,
hydraulic pressure, and air pressure are turned
off.
Remove the connector interface plate attachment
screws and carefully open the plate.
CAUTION
There are cabling attached to the plate. The plate
cannot be removed completely until the connect-
ors are removed.
Action
DANGER
Make sure that all supplies for electrical power,
hydraulic pressure, and air pressure are turned
off.
© Copyright 2022-2023 ABB. All rights reserved.
5.3.1 Replacing the cable package
Note
Valid for cabling with rear inter-
face
xx2000001558
Valid for cabling with bottom inter-
face (option 3309-1)
xx2000001575
Note
Continues on next page
5 Repair
Continued
227