5 Repair
5.5.1 Replacing the lower arm
Continued
2
3
Reconnecting the air hoses and Ethernet cabling (if equipped)
1
2
Continues on next page
370
Action
For robots with protection class IP67 (option
3350-670)
Check the gasket.
Replace if damaged.
Refit the lamp unit cover.
Action
Reconnect the air hoses.
Note
See the number markings on the air hoses for
help to find the corresponding air hoses.
For robots with Ethernet cabling
Access the connector from the process hub and
reconnect the connector.
J1.C2
Tip
See the number markings on the connectors for
help to find the corresponding connector.
© Copyright 2022-2023 ABB. All rights reserved.
Note
Gasket for lamp unit cover:
3HAC082935-001
xx2200001004
Lamp unit cover: 3HAC082320-001
Screw: M3x8 12.9 Lafre
2C2B/FC6.9 (4 pcs)
Tightening torque: 0.6 Nm
xx2200001002
Note
xx2000001539
xx2200001001
Product manual - CRB 1300