5 Repair
5.3.1 Replacing the cable package
Continued
5
Separating the cable package from the housing
1
2
Disconnecting the axis-2 and -3 motor connectors
1
2
Continues on next page
222
Action
Snap loose and remove the male head of the
connectors from the connector plate.
Action
DANGER
Make sure that all supplies for electrical power,
hydraulic pressure, and air pressure are turned
off.
Remove the axis-4 cable protector.
Action
DANGER
Make sure that all supplies for electrical power,
hydraulic pressure, and air pressure are turned
off.
Remove the connector plate.
CAUTION
Be aware of the cablings that are attached to the
connector plate! The connector plate cannot be
removed completely until the connectors are re-
move from the plate, as shown in following step.
© Copyright 2022-2023 ABB. All rights reserved.
Note
xx2000001545
Note
xx2000001546
Note
xx2000001548
Product manual - CRB 1300
3HAC083111-001 Revision: B

Advertisement