5 Repair
5.3.1 Replacing the cable package
Continued
Routing the cable package in the lower arm
1
2
3
Continues on next page
234
Action
Refit the connector plate to the cable package.
Check the axis-3 cable protector.
Replace if damaged.
Note
If replaced, apply grease to the axis-3 cable pro-
tector before refitting.
Route the cable package through the lower arm
support and up into the housing.
CAUTION
Make sure that no cables or hoses are twisted or
strained. Reroute if necessary.
© Copyright 2022-2023 ABB. All rights reserved.
Note
Screw: M4x8 12.9 Lafre
2C2B/FC6.9 (2 pcs)
Tightening torque: 2.6 Nm
xx2000001554
Grease: 3HAC029132-001
Plastic cable protector, axis 3:
3HAC064693-001
xx2000001568
Screw: M4x10 12.9 Lafre
2C2B/FC6.9 (3 pcs)
Tightening torque: 2.6 Nm
xx2000001552
xx2000001569