5 Repair
5.3.1 Replacing the cable package
Continued
3
Disconnecting CP/CS cabling (if equipped)
1
2
3
Continues on next page
218
Action
Snap loose and remove the male head of the
connectors from the connector plate.
Action
DANGER
Make sure that all supplies for electrical power,
hydraulic pressure, and air pressure are turned
off.
For robots with CP/CS cabling
Disconnect the connectors.
J1.C1
J1.C3
Tip
Take photos of the connector and cable position
before disconnecting them, to have as a reference
when reconnecting.
Snap loose and remove the male head of the
connectors from the connector plate.
© Copyright 2022-2023 ABB. All rights reserved.
Note
xx2000001535
Note
xx2000001536
xx2000001537