ABB CRB 1300 Product Manual page 132

Hide thumbs Also See for CRB 1300:
Table of Contents

Advertisement

3 Installation and commissioning
3.7.5.1 Configuration of one PROFIsafe-based laser scanner (RobotWare 7.6 or later and PLC acting
as Master)
Continued
Configuring SafeMove
To enable SafeMove, perform the following procedure:
132
Create variables.
Name
ProtectingTrigger
WarningTrigger
ProtectingArea
WarningArea
SafetyCommunicationEnable
ActivateScanner
i
%I3.X and %I4.X are the addresses of the laser scanner; %Q68.X is the address of the
OmniCore controller.
%Q3.0 is for activating the monitoring cases of the laser scanner.
Check the communication between the PLC and controller is well and activate
the laser scanner; set up the communication between the laser scanner, PLC
and OmniCore controller.
1 Log in the FlexPendant.
Make sure the user logged in have access grants to lock safety controller
configurations, safety services and software synchronization.
2 Tap SafeMove on the home page.
3 Tap Load in the pop-up message box to confirm loading of template SafeMove
configuration files.
The controller restarts.
4 After the controller is restarted, tap Settings on the home page.
5 Tap Safety Controller.
6 Tap Synchronization in the left pane.
7 Jog the robot to match the Actual Positions values with the Sync Positions
values.
Make sure the values are the same.
8 Tap Synchronize.
© Copyright 2022-2023 ABB. All rights reserved.
Type
Example address
Bool
%I3.0
Bool
%I4.1
Bool
%Q68.0
Bool
%Q68.1
Bool
%Q68.2
Bool
%Q3.0
Product manual - CRB 1300
3HAC083111-001 Revision: B
i