3HAC083111-001 Revision: B
Action
Remove the screws and carefully open the cover.
CAUTION
There is cabling attached to the cover. The cover
cannot be removed completely until the connect-
ors are removed.
Disconnect the air hoses.
For robots with Ethernet cabling
Access the connector from the process hub and
disconnect the connector.
J1.C2
Tip
Take photos of the connector and cable position
before disconnecting them, to have as a reference
when reconnecting.
Tip
The connector clip has to be pressed (1) and
pushed forward (2) to separate the J2.C2 (for
Ethernet cabling).
xx1800002943
© Copyright 2022-2023 ABB. All rights reserved.
5.7.3 Replacing the axis-3 gearbox
Note
xx2200001000
xx2000001539
xx2200001001
Continues on next page
5 Repair
Continued