3
4
Refitting the motor
Use these procedures to refit the axis-5 motor.
Refitting the axis-5 motor
1
2
Product manual - CRB 1300
3HAC083111-001 Revision: B
Action
Remove the screws and washers.
Carefully lift out the motor.
Action
Check that:
all assembly surfaces are clean and without
damages
the motor is clean and undamaged.
Orient the motor correctly and fit it into the tubular.
© Copyright 2022-2023 ABB. All rights reserved.
5 Repair
5.6.5 Replacing the axis-5 motor
Continued
Note
xx2000001596
xx2000001597
Note
Motor orientation: orient the motor
according to the figure below, in
regard to the encircled motor con-
nector.
xx2000001598
Continues on next page