3
4
Removing the lamp unit
Notice that the procedure is valid only when the lamp unit needs a replacement.
1
Product manual - CRB 1300
3HAC083111-001 Revision: B
Action
Disconnect the air hoses.
For robots with Ethernet cabling
Access the connector from the process hub and
disconnect the connector.
J1.C2
Tip
Take photos of the connector and cable position
before disconnecting them, to have as a reference
when reconnecting.
Tip
The connector clip has to be pressed (1) and
pushed forward (2) to separate the J2.C2 (for
Ethernet cabling).
xx1800002943
Action
Remove the lamp unit cover.
© Copyright 2022-2023 ABB. All rights reserved.
5.7.2 Replacing the axis-2 gearbox
Note
xx2000001539
xx2200001001
Note
xx2200001002
Continues on next page
5 Repair
Continued
569