Replacing the axis-3 mechanical stops
1
2
3
4
5
Product manual - CRB 1300
3HAC083111-001 Revision: B
Action
Jog the robot to a position where the mechanical
stops are most easily accessed.
DANGER
Turn off all:
electric power supply
hydraulic pressure supply
air pressure supply
to the robot, before entering the safeguarded
space.
Remove the mechanical stops.
Discard the old stops and refit with new ones.
Apply a little Loctite 243 to the screws.
Note
If there is locking liquid residues on the screw,
please clean it before refitting. Remove residual
locking liquid after refitting.
© Copyright 2022-2023 ABB. All rights reserved.
5.5.4 Replacing the axis-3 mechanical stops
Note
For CRB 1300-11/0.9, CRB 1300-
7/1.4 and
xx2000000507
For CRB 1300-10/1.15
xx2000000508
For CRB 1300-11/0.9, CRB 1300-
7/1.4 and
Mechanical stop, block A:
3HAC065651-001 (2 pcs)
For CRB 1300-10/1.15
Mechanical stop, block A:
3HAC065651-001 (1 pcs)
Mechanical stop, block B:
3HAC065671-001 (1 pcs)
Continues on next page
5 Repair
Continued
479