Disconnecting the axis-3 motor connectors
1
2
3
4
5
Product manual - CRB 1300
3HAC083111-001 Revision: B
Action
DANGER
Make sure that all supplies for electrical power,
hydraulic pressure, and air pressure are turned
off.
Remove the connector plate.
CAUTION
Be aware of the cablings that are attached to the
connector plate! The connector plate cannot be
removed completely until the connectors are re-
move from the plate, as shown in following step.
Cut the cable strap.
Disconnect the connectors.
FB3
MP3
Tip
Take photos of the connector and cable position
before disconnecting them, to have as a reference
when reconnecting.
Snap loose and remove the male head of the
connectors from the connector plate.
© Copyright 2022-2023 ABB. All rights reserved.
5 Repair
5.6.3 Replacing the axis-3 motor
Continued
Note
xx2000001548
xx2000001620
xx2000001619
xx2000001621
Continues on next page