5 Repair
5.5.3 Replacing the tubular and tilt unit
Continued
4
Refitting the axis-5 motor
1
2
3
Continues on next page
470
Action
Secure the motor with the screws.
Action
Check that:
all assembly surfaces are clean and without
damages
the motor is clean and undamaged.
Orient the motor correctly and fit it into the tubular.
Refit the screws and washers.
Note
Do not tighten the screws yet.
© Copyright 2022-2023 ABB. All rights reserved.
Note
Tightening torque: 6 Nm
xx2000001599
Note
Motor orientation: orient the motor
according to the figure below, in
regard to the encircled motor con-
nector.
xx2000001598
Screw: M5x16 12.9 Lafre
2C2B/FC6.9 (4 pcs)
xx2000001596