Refitting the housing
Use these procedures to refit the housing.
Refitting the axis-4 mechanical stop slider
1
Refitting the housing
1
2
3
Product manual - CRB 1300
3HAC083111-001 Revision: B
Action
Place the axis-4 mechanical stop slider in the
housing.
Action
For robots with protection class IP67 (option
3350-670)
Valid for CRB 1300-11/0.9 and CRB 1300-10/1.15
Check the O-ring.
Replace if damaged.
Valid for CRB 1300-11/0.9 and CRB 1300-10/1.15
Refit the tubular to the housing.
Valid for CRB 1300-7/1.4 and
Refit the extender unit to the housing.
© Copyright 2022-2023 ABB. All rights reserved.
5.5.2 Replacing the housing and extender unit
Note
xx2000001732
Note
O-ring on tubular: 3HAC061327-
018
xx2000002519
xx2000001728
xx2000001727
5 Repair
Continued
Continues on next page