ABB CRB 1300 Product Manual page 500

Hide thumbs Also See for CRB 1300:
Table of Contents

Advertisement

5 Repair
5.6.2 Replacing the axis-2 motor
Continued
Disconnecting the axis-2 motor connectors
1
2
3
4
5
Continues on next page
500
Action
DANGER
Make sure that all supplies for electrical power,
hydraulic pressure, and air pressure are turned
off.
Remove the connector plate.
CAUTION
Be aware of the cablings that are attached to the
connector plate! The connector plate cannot be
removed completely until the connectors are re-
move from the plate, as shown in following step.
Cut the cable strap.
Disconnect the connectors.
FB2
MP2
Tip
Take photos of the connector and cable position
before disconnecting them, to have as a reference
when reconnecting.
Snap loose and remove the male head of the
connectors from the connector plate.
© Copyright 2022-2023 ABB. All rights reserved.
Note
xx2000001548
xx2000001640
xx2000001639
xx2000001641
Product manual - CRB 1300