ABB CRB 1300 Product Manual page 513

Hide thumbs Also See for CRB 1300:
Table of Contents

Advertisement

Removing the axis-3 motor
1
2
3
4
Refitting the motor
Use these procedures to refit the axis-3 motor.
Refitting the axis-3 motor
1
Product manual - CRB 1300
3HAC083111-001 Revision: B
Action
DANGER
Make sure that all supplies for electrical power,
hydraulic pressure, and air pressure are turned
off.
CAUTION
Removing motors will release axes. This means
the axes can fall down.
Make sure axes are well supported before remov-
ing motors.
Remove the screws and washers.
Carefully lift out the motor.
Action
CAUTION
Do not mix the axis-3 motor used for CRB 1300-
7/1.4 and .
Always carefully check the part number attached
to the motor and the robot type, and refit with the
right one.
© Copyright 2022-2023 ABB. All rights reserved.
5 Repair
5.6.3 Replacing the axis-3 motor
Continued
Note
xx2000001616
xx2000001617
Note
Axis-3 motor for CRB 1300-7/1.4:
3HAC073086-001
Continues on next page
513