ABB CRB 1300 Product Manual page 149

Hide thumbs Also See for CRB 1300:
Table of Contents

Advertisement

3.7.5.5 Configuration of one SafetyIO-base laser scanner (RobotWare 7.6 or later)
Product manual - CRB 1300
3HAC083111-001 Revision: B
3 Tap Load in the pop-up message box to confirm loading of template SafeMove
configuration files.
The controller restarts.
4 After the controller is restarted, tap Settings on the home page.
5 Tap Safety Controller.
6 Tap Synchronization in the left pane.
7 Jog the robot to match the Actual Positions values with the Sync Positions
values.
Make sure the values are the same.
8 Tap Synchronize.
© Copyright 2022-2023 ABB. All rights reserved.