5 Repair
5.5.3 Replacing the tubular and tilt unit
Continued
2
Refitting the process hub
1
2
3
Continues on next page
464
Action
Reconnect the connectors.
FB6
MP6
Tip
See the number markings on the connectors for
help to find the corresponding connector.
Action
Check the air hoses.
Replace the cable package if damaged. See
placing the cable package on page
For robots with protection class IP67 (option
3350-670)
Check the gasket.
Replace if damaged.
For robots with protection class IP67 (option
3350-670)
Check the seal bolts.
Replace if damaged.
© Copyright 2022-2023 ABB. All rights reserved.
Note
xx2000001532
Note
Re-
211.
xx2000001539
Gasket for process hub:
3HAC070887-001
xx2000002512
Seal bolt: 3HAC032050-001
xx2000002513
Product manual - CRB 1300
3HAC083111-001 Revision: B