5 Repair
5.4.1 Replacing the base
Continued
6
7
Putting the base on its side
1
2
Refitting the axis-1 motor
1
Continues on next page
274
Action
Secure with screws.
Mark the screws aligned with the oil openings.
Action
DANGER
Make sure that all supplies for electrical power,
hydraulic pressure, and air pressure are turned
off.
Put the base on its side for easily refitting the
motor and base cover.
Action
Check that:
all assembly surfaces are clean and without
damages
the motor is clean and undamaged.
© Copyright 2022-2023 ABB. All rights reserved.
Note
Screw: M6x65 12.9 Gleitmo
603+Geomet 500 (12 pcs)
Tightening torque: 11.5 Nm
xx2000001694
xx2000001698
Note
Note
Product manual - CRB 1300
3HAC083111-001 Revision: B