ABB CRB 1300 Product Manual page 251

Hide thumbs Also See for CRB 1300:
Table of Contents

Advertisement

3
4
5
Removing the battery pack
1
2
3
Product manual - CRB 1300
3HAC083111-001 Revision: B
Action
Remove the SMB cover attachment screws and
carefully open the cover.
CAUTION
Clean cover from metal residues before opening.
Metal residues can cause shortage on the boards
which can result in hazardous failures.
CAUTION
There are cabling attached to the cover. The
cover cannot be removed completely until the
connectors are removed.
Disconnect the connectors.
SMB.J1
SMB.J2
R2.SMB
Tip
Take photos of the connector and cable position
before disconnecting them, to have as a reference
when reconnecting.
Remove the SMB cover completely from the base.
Action
DANGER
Make sure that all supplies for electrical power,
hydraulic pressure, and air pressure are turned
off.
ELECTROSTATIC DISCHARGE (ESD)
The unit is sensitive to ESD. Before handling the
unit read the safety information in section
unit is sensitive to ESD on page
Disconnect the battery cable.
© Copyright 2022-2023 ABB. All rights reserved.
5.3.2 Replacing the SMB unit
Note
xx2000001503
xx2000001504
Note
The
49.
xx2000001505
5 Repair
Continued
Continues on next page
251