5 Repair
5.5.3 Replacing the tubular and tilt unit
Continued
3
Disconnecting the axis-5 motor connectors
1
2
3
Disconnecting CP/CS cabling (if equipped)
1
Continues on next page
440
Action
Snap loose and remove the male head of the
connectors from the connector plate.
Action
DANGER
Make sure that all supplies for electrical power,
hydraulic pressure, and air pressure are turned
off.
Disconnect the connectors.
MP5
FB5
Tip
Take photos of the connector and cable position
before disconnecting them, to have as a reference
when reconnecting.
Snap loose and remove the male head of the
connectors from the connector plate.
Action
DANGER
Make sure that all supplies for electrical power,
hydraulic pressure, and air pressure are turned
off.
© Copyright 2022-2023 ABB. All rights reserved.
Note
xx2000001533
Note
xx2000001534
xx2000001535
Note
Product manual - CRB 1300