5
Reconnecting the axis-1 motor connectors
1
2
3
Product manual - CRB 1300
3HAC083111-001 Revision: B
Action
Arrange the connectors as follows (facing the
SMB side):
•
Right of the connector plate:
- SMB.J1
- SMB.J2
- R2.MP1 on axis-1 motor
- R2.FB1 on axis-1 motor
•
Left of the connector plate:
- R2.SMB
- R2.MP1 on main cable package
- R2.FB1 on main cable package
Action
Insert the male header of the motor connectors
to the connector plate.
Reconnect the connectors.
•
FB1
•
MP1
Tip
See the number markings on the connectors for
help to find the corresponding connector.
Route and secure the cabling with cable straps.
CAUTION
Correct cable routing is highly important.
If the cables are routed and secured incorrectly
the cables can be damaged.
© Copyright 2022-2023 ABB. All rights reserved.
5.3.1 Replacing the cable package
Note
Note
xx2000001561
xx2000001560
Continues on next page
5 Repair
Continued
231