5 Repair
5.3.1 Replacing the cable package
Continued
2
3
Disconnecting the brake release connector
1
2
3
4
Continues on next page
228
Action
Valid for cabling with bottom interface (option
3309-1)
Remove the base rear cover.
Disconnect the earth cable.
Action
DANGER
Make sure that all supplies for electrical power,
hydraulic pressure, and air pressure are turned
off.
ELECTROSTATIC DISCHARGE (ESD)
The unit is sensitive to ESD. Before handling the
unit read the safety information in section
unit is sensitive to ESD on page
Cut the cable strap.
Disconnect the connector.
R2.BRU
Tip
Take photos of the connector and cable position
before disconnecting them, to have as a reference
when reconnecting.
© Copyright 2022-2023 ABB. All rights reserved.
Note
xx2000001573
xx2000001574
Note
The
49.
xx2100001480
Product manual - CRB 1300
3HAC083111-001 Revision: B