5 Repair
5.5.1 Replacing the lower arm
Continued
Reconnecting the axis-2 and -3 motor connectors
1
2
3
4
Continues on next page
366
Action
Insert the male header of the motor connectors
to the connector plate.
Route and secure the cabling with cable straps.
CAUTION
Correct cable routing is highly important.
If the cables are routed and secured incorrectly
the cables can be damaged.
Reconnect the connectors.
FB2
MP2
FB3
MP3
Tip
See the number markings on the connectors for
help to find the corresponding connector.
Refit the connector plate to the lower arm.
© Copyright 2022-2023 ABB. All rights reserved.
Note
xx2000001551
xx2000001549
xx2000001550
Screw: M4x8 12.9 Lafre
2C2B/FC6.9 (2 pcs)
Tightening torque: 2.6 Nm
xx2000001548
Product manual - CRB 1300
3HAC083111-001 Revision: B