5 Repair
5.7.3 Replacing the axis-3 gearbox
Continued
2
3
4
5
Pulling out the cable package
1
Continues on next page
612
Action
Remove the connector plate.
CAUTION
Be aware of the cablings that are attached to the
connector plate! The connector plate cannot be
removed completely until the connectors are re-
move from the plate, as shown in following step.
Cut the cable straps.
Disconnect the connectors.
FB2
MP2
FB3
MP3
Tip
Take photos of the connector and cable position
before disconnecting them, to have as a reference
when reconnecting.
Snap loose and remove the male head of the
connectors from the connector plate.
Action
DANGER
Make sure that all supplies for electrical power,
hydraulic pressure, and air pressure are turned
off.
© Copyright 2022-2023 ABB. All rights reserved.
Note
xx2000001548
xx2000001549
xx2000001550
xx2000001551
Note