3
4
5
Separating the cable package from the lower arm
1
Product manual - CRB 1300
3HAC083111-001 Revision: B
Action
Cut the cable straps.
Disconnect the connectors.
FB2
MP2
FB3
MP3
Tip
Take photos of the connector and cable position
before disconnecting them, to have as a reference
when reconnecting.
Snap loose and remove the male head of the
connectors from the connector plate.
Action
DANGER
Make sure that all supplies for electrical power,
hydraulic pressure, and air pressure are turned
off.
© Copyright 2022-2023 ABB. All rights reserved.
5 Repair
5.5.1 Replacing the lower arm
Continued
Note
xx2000001549
xx2000001550
xx2000001551
Note
Continues on next page