ABB CRB 1300 Product Manual page 245

Hide thumbs Also See for CRB 1300:
Table of Contents

Advertisement

4
Refitting the connector interface plate
1
2
3
Product manual - CRB 1300
3HAC083111-001 Revision: B
Action
Refit the SMB cover to the base.
Action
For robots with protection class IP67 (option
3350-670)
Check the gasket.
Replace if damaged.
For robots with protection class IP67 (option
3350-670)
Check the seal bolt.
Replace if damaged.
Route and secure the cabling with cable straps.
CAUTION
Correct cable routing is highly important.
If the cables are routed and secured incorrectly
the cables can be damaged.
© Copyright 2022-2023 ABB. All rights reserved.
5.3.1 Replacing the cable package
Note
Screw: M4x10 12.9 Lafre
2C2B/FC6.9 (6 pcs)
Tightening torque: 2.6 Nm
xx2000001503
Note
Gasket for base cover:
3HAC067819-001
xx2000002514
Seal bolt: 3HAC032050-001
xx2000002515
Continues on next page
5 Repair
Continued
245