ABB CRB 1300 Product Manual page 244

Hide thumbs Also See for CRB 1300:
Table of Contents

Advertisement

5 Repair
5.3.1 Replacing the cable package
Continued
2
3
Reconnecting the SMB connectors
1
2
3
Continues on next page
244
Action
Reconnect the earth cable.
Valid for cabling with bottom interface (option
3309-1)
Refit the base rear cover.
Action
ELECTROSTATIC DISCHARGE (ESD)
The unit is sensitive to ESD. Before handling the
unit read the safety information in section
unit is sensitive to ESD on page
Reconnect the connectors.
SMB.J1
SMB.J2
R2.SMB
Tip
See the number markings on the connectors for
help to find the corresponding connector.
Route and secure the cabling with cable straps.
CAUTION
Correct cable routing is highly important.
If the cables are routed and secured incorrectly
the cables can be damaged.
© Copyright 2022-2023 ABB. All rights reserved.
Note
xx2000001574
Screw: M4x10 12.9 Lafre
2C2B/FC6.9 (8 pcs)
Tightening torque: 2.6 Nm
xx2000001573
Note
The
49.
Tightening torque: 0.3 Nm
xx2000001504
Product manual - CRB 1300
3HAC083111-001 Revision: B