3 Installation and commissioning
3.7.4.2 Configuration of SafeMove using Visual SafeMove in RobotStudio
Continued
Uploading the settings to the controller
128
3 Click Tool Position Supervision in the Modify ribbon tab and set the
properties.
Parameter
Activation
Function active status
Violation action
Settings
4 In the Visual SafeMove browser, right-click Tool Speed Supervisions and
choose Create Global Tool Speed Supervision.
Parameter
Activation
Function active status
Violation action
Settings
5 In the Visual SafeMove browser, right-click Stand Still Supervisions and
choose Create Global Stand Still Supervision.
Parameter
Activation
Function active status
Violation action
Tolerances
1 In the Visual SafeMove ribbon tab, click Controller in the Configuration
group.
2 Click Write to controller.
The configurations are uploaded to the controller after the controller restarts.
© Copyright 2022-2023 ABB. All rights reserved.
Value
PermanentlyActive
No signal
Stop category
Category1Stop
Signal
No signal
Checked the Include upper arm
geometry and Allow inside
check boxes.
Value
ISH_Supervise_TSP
ISH_TSP_Active
Stop category
Category1Stop
Signal
ISH_TSP_Viol
Max speed (mm/s)
250.000
Min speed (mm/s)
Leave blank
Value
ISH_Supervise_SST
ISH_SST_Active
Stop category
Category0Stop
Signal
ISH_SST_Viol
Enabled for all joints and remain
default tolerance values.