ABB CRB 1300 Product Manual page 538

Hide thumbs Also See for CRB 1300:
Table of Contents

Advertisement

5 Repair
5.6.5 Replacing the axis-5 motor
Continued
Reconnecting the axis-6 motor connectors
1
2
Securing the cable package in the tubular
1
2
Continues on next page
538
Action
Insert the male header of the motor connectors
to the connector plate.
Reconnect the connectors.
FB6
MP6
Tip
See the number markings on the connectors for
help to find the corresponding connector.
Action
Refit the connector plate.
Route and secure the cabling with cable straps.
CAUTION
Correct cable routing is highly important.
If the cables are routed and secured incorrectly
the cables can be damaged.
© Copyright 2022-2023 ABB. All rights reserved.
Note
xx2000001533
xx2000001532
Note
Screw: M3x8 12.9 Lafre
2C2B/FC6.9 (2 pcs for each plate)
Tightening torque: 1.3 Nm
xx2000001531
xx2000001530
Product manual - CRB 1300
3HAC083111-001 Revision: B

Advertisement